Fire Rated Wood Double Door
UL 10C LISTED • IBC 2021 COMPLIANT
UL Listed Wood Fire Doors – 20, 45, 60 & 90 Minute Ratings
Bastion supplies UL-listed wood pairs with the required coordinator or astragal-mounted sequencing, surface or
concealed vertical-rod panic devices, and a labeled frame. Pair and double-egress configurations are strictly listing-controlled.
Product Highlights
- Overlapping astragal and UL-listed coordinators
- Active / inactive leaf factory coordination
- Flush bolts, panic devices and closers prepped
- Ratings 20–90 minutes on mineral cores
- Up to 8' x 8' pair openings
- Hardwood veneer / HPL faces
- WHI label per leaf
⏱ Quick Response • Factory Direct Delivery • Free Preliminary Quote
Why Choose Our Fire-Rated Wood Doors
Three pillars that set us apart from US distributors and generic suppliers

Factory-Direct Pricing
Skip the distributor markup. Buy directly from the manufacturer and save 20–40% on your project cost. 15 years of experience, 500,000+ doors annual capacity — reliable bulk delivery you can count on.

Full Range UL/CE Ratings
From 20-minute to 3-hour ratings, all certified to UL 10C / NFPA 252 standards. WHI labels shipped with every door. One supplier covers every opening rating requirement in your project — no need to source from multiple vendors.

Quick Quote
For standard configurations and complete specifications, our team strives to provide a preliminary quote within 20 minutes.
Fire Rated Wood Doors Specifications
Our commercial wood doors are constructed of the highest grade steel and with the following specifications:
● Door Thickness: Standard 1-3/4 inches
● Door Core: Particleboard core
● Construction: 5-ply bonded construction
● Stiles and Rails: Fire-retardant treated hardwood
● Vision Panel: Fire-rated vision panel
● Hinges: UL-certified fire door hinges
● Lockset: Fire-rated lockset
● Door Closer: Fire-rated door closer
● Smoke Seal: Smoke and draft control seal
● Customization: Dimensions / Veneer / Hardware / Finish
● Fire Test: UL 10C / UL 10B
● Installation: Per NFPA 80 standards
Fire Ratings Explained
Choose the right UL fire rating for your application — all certified to UL 10C / NFPA 252
Corridors, office partitions, non-rated walls requiring smoke control.
1-hour fire wall openings, stairwells, hotel guest room corridors.
1-hour fire barriers, exit enclosures, vertical shaft separations.
1.5-hour fire walls, hazardous area enclosures, industrial separations.

All ratings come with WHI certification labels affixed to each door. Verify authenticity online via WHI directory.
Door Sizes (All doors = 1-3/4″ thickness)
6′8″ Height
| Door Call Size | Nominal Width | Nominal Height |
|---|---|---|
| 2068 | 2′0″ (24 inch) | 6′8″ (80 inch) |
| 2468 | 2′4″ (28 inch) | 6′8″ (80 inch) |
| ⭐️2668 | 2′6″ (30 inch) | 6′8″ (80 inch) |
| 2868 | 2′8″ (32 inch) | 6′8″ (80 inch) |
| 21068 | 2′10″ (34 inch) | 6′8″ (80 inch) |
| 3468 | 3′4″ (40 inch) | 6′8″ (80 inch) |
| 3668 | 3′6″ (42 inch) | 6′8″ (80 inch) |
| 3868 | 3′8″ (44 inch) | 6′8″ (80 inch) |
| 4068 | 4′0″ (48 inch) | 6′8″ (80 inch) |
7′0″ Height
| Door Call Size | Nominal Width | Nominal Height |
|---|---|---|
| 2070 | 2′0″ (24 inch) | 7′0″ (84 inch) |
| 2470 | 2′4″ (28 inch) | 7′0″ (84 inch) |
| ⭐️2670 | 2′6″ (30 inch) | 7′0″ (84 inch) |
| 2870 | 2′8″ (32 inch) | 7′0″ (84 inch) |
| 21070 | 2′10″ (34 inch) | 7′0″ (84 inch) |
| 3470 | 3′4″ (40 inch) | 7′0″ (84 inch) |
| 3670 | 3′6″ (42 inch) | 7′0″ (84 inch) |
| 3870 | 3′8″ (44 inch) | 7′0″ (84 inch) |
| 4070 | 4′0″ (48 inch) | 7′0″ (84 inch) |
8′0″ Height
| Door Call Size | Nominal Width | Nominal Height |
|---|---|---|
| 2080 | 2′0″ (24 inch) | 8′0″ (96 inch) |
| 2480 | 2′4″ (28 inch) | 8′0″ (96 inch) |
| ⭐️2680 | 2′6″ (30 inch) | 8′0″ (96 inch) |
| 2880 | 2′8″ (32 inch) | 8′0″ (96 inch) |
| 21080 | 2′10″ (34 inch) | 8′0″ (96 inch) |
| 3480 | 3′4″ (40 inch) | 8′0″ (96 inch) |
| 3680 | 3′6″ (42 inch) | 8′0″ (96 inch) |
| 3880 | 3′8″ (44 inch) | 8′0″ (96 inch) |
| 4080 | 4′0″ (48 inch) | 8′0″ (96 inch) |
Configuration Options
Build your door with these customizable options — all factory-prepped for easy installation
Frame Type
/
Panel Styles

Welded
Frame Type

Knocked Down (KD)
Frame Type

Vision Lite
With glass window

Louvered
Ventilation grille
Swing Direction & Handing

LH (Left Hand)
Hinges on left, swings in

RH (Right Hand)
Hinges on right, swings in

LHR (Left Hand Reverse)
Hinges on left, swings out

RHR (Right Hand Reverse)
Hinges on right, swings out
Door Finish Would

Unfinished
(Rotary Natural Birch)
Stain Grade - Finish on Site

Wheat
(Rotary Natural Birch)

Pecan
(Rotary Natural Birch)

Cherry
(Rotary Natural Birch)
Swing Direction & Handing
Hardware Prep

Hinge Mortise Prep
Lock Body Prep

Door Closer Prep

Panic Device Prep
Seals & Accessories
Complete your fire door assembly with UL-listed accessories — one-stop solution

Floor Stop
ANSI/BHMA Grade 1 certified floor stop built. fully compliant with NFPA 80, ADA, and California Prop 65.

Threshold
Aluminum/saddle threshold, adjustable height, fire-rated gasketing.
Door Sweep
Bottom seal with neoprene insert, smoke and draft control.

Intumescent Seal
Fire-activated expanding seal, perimeter gasketing for smoke control.

Rain Drip / Canopy
Exterior door weather protection, aluminum hood with drip edge.

Kick Plate
Stainless steel or brass kick plate, 8″/10″/12″ heights available.
Smoke Seal
UL-listed smoke and draft control gasketing, perimeter installation.

Hinges & Closers
UL-listed spring hinges, ball-bearing hinges, and door closers.
Detailed Product Description
Technical Features
- Configuration: double leaf (pairs) with overlapping astragal
- Fire Ratings: 20 / 45 / 60 / 90 minutes (UL 10C / NFPA 252)
- Max Pair Width: up to 8' x 8' (per rating)
- Hardware: coordinators, panic devices, flush bolts, closers
- Core: mineral composite (45–90 min) / FR particleboard (20 min)
Construction & Fire Performance
A fire-rated double door must seal across the meeting edge — that is the job of the overlapping astragal and the coordinator, which forces the inactive leaf home before the active leaf closes so the latch engages. Our pairs are engineered and factory-prepped as a unit, with fire-rated intumescent seals along the meeting edge and perimeter. Each leaf carries its own WHI label, and the full pair is tested to UL 10C / NFPA 252 for its rating.
Applications
Hospital corridors and patient wings, school auditoriums and gyms, hotel function rooms, lobbies, mechanical and equipment rooms with wide openings.
Frequently Asked Questions
Common questions from buyers, contractors, and distributors
Send Your Project Specs
Tell us your project requirements — door sizes, fire ratings, hardware, quantities, and destination port. Our team will respond with a detailed quote within 24 hours.
Quick Quote Checklist: For the fastest response, include: ① Quantity & door sizes (W×H) ② Fire rating required (20/45/60/90 min or 3hr) ③ Hardware schedule (hinges/lock/closer) ④ Glass/louver requirements ⑤ Finish color (RAL#) ⑥ Destination port & target delivery date.
Get in touch
We're Ready To Assist You Anytime